تخطي للذهاب إلى المحتوى

Carrier Miraco Fan Coil Units in Egypt — Concealed Ducted FCU Range

Three series, 29 models with catalogue data, for consultants, contractors and procurement teams. Selection from the load schedule — proposals with an engineering check table and submittal. النسخة العربية: فان كويل للمشاريع

Short answer

El Shora Cooling Solutions (شركة الشورى لحلول التبريد والتكييف والتهوية) is an Egyptian HVAC contractor based in 6th of October City, founded in 2016. It supplies and installs Carrier Miraco chilled-water fan coil units (made in Egypt) for malls, hotels, hospitals and office buildings across Egypt: the 42MKT3 Aqua Slim range (24.3 cm high, 3-row coil, 50 Pa, 7/12 °C), the 42MKS4 district-cooling range (4-row coil rated at 5.5/14.5 °C), the 42MKT4 4-row range (7/12 °C, 30 Pa) and 100 Pa high-static models — 400 to 2,200 CFM. Units are selected from the load schedule, water temperatures and external static pressure, and every proposal carries an engineering check table and a submittal. No published prices — +20 2 3691 4695, WhatsApp +20 110 057 4656.

Content last reviewed: 3 November 2026

The three series — and the high-static models

SeriesCoilExternal staticRated waterAirflow rangeTypical use
42MKT3 Aqua Slim3 rows, 7 mm tubes (9.52 mm on 1200/1400)50 Pa7 / 12 °C400–1,400 CFMLow ceilings: hotel rooms, offices, villas on chilled water — only 24.3 cm high
42MKS4 District Cooling4 rows, 9.52 mm tubes30 Pa (400–600) / 50 Pa (600 Plus, 800–2,000)5.5 / 14.5 °C (ΔT 9 K)400–2,000 CFMMall shops and towers on district-cooling networks
42MKT44 rows, 9.52 mm tubes30 Pa7 / 12 °C400–1,200 CFMHigher loads per CFM, higher latent loads, short duct runs
42MKT3H / 42MKT4H (G100)3 or 4 rows100 Paproject water temperatures1,600–2,200 CFM nominalLong duct runs, many outlets, extra filters — full datasheet sent with the proposal

The units, from the catalogues

Carrier Miraco 42MKT3 Aqua Slim fan coil unit, 24.3 cm high

42MKT3 Aqua Slim — 3-row coil, 24.3 cm high

Carrier Miraco 42MKS4 district cooling fan coil unit

42MKS4 — 4-row coil rated at 5.5/14.5 °C

Carrier Miraco 42MKT4 4-row fan coil unit

42MKT4 — 4-row coil at 7/12 °C

Full range — 29 models with catalogue data

Airflow in CFM at high/medium/low speed; cooling capacity in kW at medium speed (the speed normally used for selection); dimensions length × height × depth in cm.

ModelSeriesRowsESP (Pa)Airflow CFM H/M/LCooling kW (medium)Dimensions cm
42MKT3(7)-400G50A42MKT3 slim (24.3 cm)350425/266/1682.8390.8 × 24.3 × 48.2
42MKT3(7)-500G50A42MKT3 slim (24.3 cm)350494/347/1853.7390.8 × 24.3 × 48.2
42MKT3(7)-600G50A42MKT3 slim (24.3 cm)350625/403/2304.21100.3 × 24.3 × 48.2
42MKT3(7)-800G50A42MKT3 slim (24.3 cm)350878/627/3796.5136.8 × 24.3 × 48.2
42MKT3(7)-1000G50A42MKT3 slim (24.3 cm)3501012/879/6748.06136.8 × 24.3 × 48.2
42MKT3(9)-1200G50A42MKT3 slim (24.3 cm)3501206/925/5668.39165.8 × 24.3 × 48.2
42MKT3(9)-1400G50A42MKT3 slim (24.3 cm)3501367/1142/84410.54189.8 × 24.3 × 48.2
42MKS4-400G3042MKS4 district cooling430351/288/2133.4394.1 × 24.1 × 52.2
42MKS4-500G3042MKS4 district cooling430428/408/3514.3394.1 × 24.1 × 52.2
42MKS4-600G3042MKS4 district cooling430559/530/4376.14116.1 × 24.1 × 52.2
42MKS4-600G50-Plus42MKS4 district cooling Plus450664/627/5544.96116.1 × 24.1 × 52.2
42MKS4-800G50-A442MKS4 district cooling450748/718/6566.69118 × 34 × 61.2
42MKS4-1000G50-A442MKS4 district cooling450856/821/7737.33118 × 34 × 61.2
42MKS4-1200G50-A442MKS4 district cooling4501138/983/8919.12136.9 × 34 × 61.2
42MKS4-1400G50-A442MKS4 district cooling4501284/1088/97510.3136.9 × 34 × 61.2
42MKS4-1600G50-A442MKS4 district cooling4501412/1183/107810.72136.9 × 34 × 61.2
42MKS4-1800G50-A442MKS4 district cooling4501708/1396/120413.09150 × 34 × 61.2
42MKS4-2000G50-A442MKS4 district cooling4501907/1586/133714.15150 × 34 × 61.2
42MKT4-400G3042MKT4 4-row (7/12)430400/300/2003.4391.2 × 24.1 × 50.6
42MKT4-600G3042MKT4 4-row (7/12)430600/450/3005.4113.5 × 24.1 × 50.6
42MKT4-800G3042MKT4 4-row (7/12)430800/600/4006.61143.5 × 24.1 × 50.6
42MKT4-1000G3042MKT4 4-row (7/12)4301000/750/5008.09154 × 24.1 × 50.6
42MKT4-1200G3042MKT4 4-row (7/12)4301200/900/6009.74183 × 24.1 × 50.6
42MKT4H-1600G100High static G10041001600 nominal——
42MKT4H-1800G100High static G10041001800 nominal——
42MKT4H-2200G100High static G10041002200 nominal——
42MKT3H-1600G100High static G10031001600 nominal——
42MKT3H-1800G100High static G10031001800 nominal——
42MKT3H-2200G100High static G10031002200 nominal——

Rating conditions: 42MKT3 and 42MKT4 at 7 °C entering / 12 °C leaving water and 27 °C DB / 19 °C WB air; 42MKS4 at 5.5 / 14.5 °C water and 27 °C DB / 19 °C WB air (600 Plus at 24 °C DB / 18 °C WB). All units 220–240 V single phase, three speeds, two-pipe, 16 bar maximum water pressure, RC ¾" water connections.

What we need for a correct selection

  • Load schedule per space — total and sensible load and its source (HAP, manual calculation or the mall template).
  • Entering and leaving water temperatures — 7/12, 5.5/14.5 or the project's own pair; the same model delivers a different capacity on each.
  • External static pressure required — from duct length, number of grilles and filters (30, 50 or 100 Pa).
  • Ceiling void height — below 30 cm above the false ceiling the 24.3 cm slim range is the answer.
  • Control valve type — PICV, two-way or three-way, from the project or mall requirements.
  • Fresh air quantity and source, connection hand (right as standard, left on request) and electric heater option, and BMS integration.

What our technical proposal includes

SectionContent
Design basisProject, shop, area, water temperatures, connection type, cooling load and its source, design revision
Proposed equipmentEach model with its catalogue photo and key data: rows, tubes, ESP, capacity, airflow, dimensions, weight
Engineering checksWater ΔT, network pressure drop against the available head, water velocity, control valve, load consistency — compliant / review flags
Connection detailSupply and return line per unit: isolation valves, flushing bypass, strainer, test points, flexible hoses, dielectric coupling, air vent
ControlsThermostat per unit or zone with a valve output, ready for BMS integration
Network resultsTotal flow, critical path and pressure drop per segment — with the chilled-water network report as an annex
Exclusions and financial offerTie-in point, BTU meter, power supply and permits named explicitly; then items and quantities

For procurement teams

  • Vendor registration documents ready: commercial register, tax card, VAT certificate.
  • Tax invoices for companies.
  • Payment by bank transfer, cheque, cash or instalments against delivery milestones.
  • Projects served across Egypt; supply from the agent's stores or El Shora's warehouse in 6th of October City.

Frequently asked questions

Are these fan coil units made in Egypt?

Yes. The 42MKT3, 42MKS4 and 42MKT4 ranges are manufactured in Egypt by Miraco, Carrier's Egyptian manufacturer, and El Shora works from the manufacturer's technical catalogues.

What is the difference between the 42MKT3, 42MKS4 and 42MKT4 series?

42MKT3 (Aqua Slim) is 24.3 cm high with a 3-row coil and 50 Pa external static pressure, rated at 7/12 °C water. 42MKS4 has a 4-row coil and its catalogue capacities are rated at 5.5/14.5 °C water, as district-cooling networks in malls require. 42MKT4 has a 4-row coil at 7/12 °C and 30 Pa for higher loads with short duct runs.

What do G30, G50 and G100 mean in the model code?

The external static pressure in pascals available for ducts and grilles: 30 Pa for short runs, 50 Pa as the standard for a ducted room, and 100 Pa (42MKT3H / 42MKT4H, 1,600–2,200 CFM) for long duct runs with several outlets or extra filters.

Can you supply only, without installation?

Yes. Supply-only to contractors against a purchase order, or supply, installation and commissioning together with the chilled-water piping, ducts and grilles in one bill of quantities.

How much does a fan coil unit cost?

No prices are published for fan coil units: the model itself is only fixed after the load schedule, the water temperatures and the external static pressure are known. Send these and you receive a written technical and financial proposal.

What does your technical proposal include?

Design basis, the proposed units with catalogue photo and key data, an engineering check table (water ΔT, network pressure drop against the available head, water velocity, control valve type, load consistency), the typical connection detail per unit, controls, chilled-water network results and named exclusions — in Arabic or English.

Can you register as a vendor and issue tax invoices?

Yes. Commercial register, tax card and VAT certificate are ready for vendor registration; tax invoices are issued for companies. Payment by bank transfer, cheque, cash or instalments against delivery milestones. Projects are served across Egypt.

Send us the load schedule

Load schedule, water temperatures and the external static pressure required. You receive a technical proposal with each model's photo and data and an engineering check table.